This is a working overview of stationary phase, written for readers who want more than a one-paragraph summary but less than a textbook.
This page was last updated on 2026-05-09 and is reviewed periodically as new material appears.
Routine HPLC testing compares a sample result with a calibration curve prepared from known reference standards. Peak area or peak height is plotted against concentration, and the curve is used to estimate unknown amounts. Retention time supports tentative identification when compared with a standard, though mass spectrometry or another confirmatory method may be needed for definitive identification. Pre-run checks verify repeatability, resolution, and peak symmetry before sample analysis. Limits of detection and quantification describe the smallest amounts that can be reliably observed or measured. Sample preparation, filtration, and degassing help prevent column damage and inconsistent results.
High-performance liquid chromatography is an analytical technique that separates components in a liquid sample. A pump moves a liquid mobile phase through a column packed with a solid stationary phase. Compounds interact differently with both phases and travel at different rates, leaving the column at distinct retention times. A detector records these arrivals as peaks on a chromatogram. The resulting pattern supports identification and quantification of substances in mixtures. Modern instruments use high pressure to force solvent through small particles, which improves speed and resolution compared with older low-pressure liquid chromatography methods.
Separation in HPLC depends on the chemistry of the stationary phase, the composition of the mobile phase, and the physical properties of the column. Reverse-phase separations use a nonpolar stationary phase and a polar mobile phase, and they are common for many organic compounds. Ion-exchange, size-exclusion, and normal-phase modes serve other classes of analytes. Gradient elution changes solvent strength over time, while isocratic elution holds it constant. Flow rate, temperature, particle size, and column length all influence peak shape and resolution. Detection may use ultraviolet absorbance, fluorescence, refractive index, or mass spectrometry, depending on the analyte and the required sensitivity.
Routine quality control uses system suitability, blank injections, check standards, and control samples to detect drift or contamination. System suitability criteria may specify minimum resolution, maximum tailing factor, and a permitted range for repeated injections. Blank injections reveal carryover or solvent contamination, while check standards confirm calibration accuracy over a batch. Control samples with known analyte levels can show whether results remain within statistical limits. When a control result falls outside limits, the analyst investigates the cause and may invalidate affected results before repeating the batch.
Documentation and traceability are central to regulated HPLC testing. Records typically include instrument logs, column history, mobile-phase preparation, sample preparation, injection sequences, raw chromatograms, and audit trails. Electronic systems may require user access controls, time-stamped changes, and backup procedures. Training records show that analysts are qualified for assigned methods. Audits and inspections check whether written procedures match actual practice and whether deviations are documented. These controls support reproducibility and allow results to be reconstructed if questions arise later.
| Property | Value | Notes |
|---|---|---|
| Common abbreviation | HPLC | High-performance liquid chromatography |
| Separation basis | Differential partitioning | Between liquid mobile phase and solid stationary phase |
| Common mode | Reverse phase | Nonpolar column, polar mobile phase |
| Typical detector | UV-Vis absorbance | Widely used for compounds with chromophores |
| Typical column particle size | 2–5 µm | Smaller particles can improve resolution |
Quality control samples are inserted at intervals to monitor accuracy and precision throughout a batch. Blank samples detect contamination, while spiked samples assess recovery from the sample matrix. Calibration standards establish the relationship between detector response and concentration, and control samples are prepared independently from them whenever possible. Laboratories also participate in proficiency testing and maintain audit trails, instrument logs, and reagent records. Ongoing review of control charts can reveal trends before they cause out-of-specification results.
Method validation demonstrates that an HPLC procedure is suitable for its intended purpose. Common validation parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantification, and robustness. Accuracy reflects agreement with a reference value, while precision describes repeatability under defined conditions. Specificity shows whether the method can measure the analyte in the presence of impurities or matrix components. Validation documents are reviewed before a method is used for routine testing or regulatory submissions.
Validation demonstrates that a method is suitable for its intended use. Typical performance characteristics include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Regulators and standards organizations provide frameworks, but specific requirements depend on the application and jurisdiction. System suitability tests are run before sample analysis to confirm resolution, peak symmetry, retention time repeatability, and sensitivity. A validated method is not permanently fixed; changes may require partial or full revalidation.
Routine HPLC testing depends on controlled reagents, calibrated instruments, and documented procedures. Columns degrade over time, so retention times and peak shapes are monitored for drift. Mobile phases are filtered and degassed to prevent pump damage and detector noise. Reference standards must be traceable and stored under suitable conditions. Data handling systems record injections, calculations, and audit trails. Quality control samples interspersed with unknowns help detect errors during a run.
In physics, atomic spectroscopy is the study of the electromagnetic radiation absorbed and emitted by atoms. Since unique elements have unique emission spectra, atomic spectroscopy is applied for determination of elemental compositions. It can be divided by atomization source or by the type of spectroscopy used. In the latter case, the main division is between optical and mass spectrometry. Mass spectrometry generally provides significantly better analytical performance but is also significantly more complex. This complexity translates into higher purchase costs, higher operational costs, more operator training, and a greater number of components that can potentially fail. Because optical spectroscopy is often less expensive and has performance adequate for many tasks, it is far more common. Atomic absorption spectrometers are one of the most commonly sold and used analytical devices.
Within the field of supramolecular polymerization, Schmatloch et al. used automated synthesis to create main-chain supramolecular coordination polymers, reacting bis(2,2′:6′,2″-terpyridine)-functionalized poly(ethylene oxide) with various metal(II) acetates. From this, it was revealed that classical laboratory approaches could be transferred to automatic synthesis, optimizing the processes to increase efficiency and aid with reproducibility.
The 2014 Ebola outbreak killed more than 11,300 people. In the Democratic Republic of Congo (DRC), as of January 2020, this is the second largest outbreak with over 3,400 confirmed or probable cases, including more than 2,200 deaths. Regeneron used its VelociGene, VelocImmune, and VelociMab antibody discovery and production technologies and coordinated with the U.S. government's Biomedical Advanced Research and Development Authority (BARDA). The therapy was developed in 6 months and a Phase 1 trial in healthy humans was completed in 2015.
Three dimensional structure of none of the members of Angiopoietin like proteins (ANGPTLs) is available up until now. However, the structure of ANGPTL8 was predicted by homology modeling and is also reported in literature. It consists of alpha helices and its sequence show high similarity with the coiled-coil domains of ANGPTL3 and ANGPTL4. The ANGPTL8 regulatory pathway has been constructed recently by integrating the information of its known transcription factors which is available at WikiPathways data repository with the pathway id WP3915.
Sources: en.wikipedia.org
AlphaFold 1 (2018) was built on work developed by various teams in the 2010s, work that looked at the large databases of related protein sequences now available from many different organisms (most without known 3D structures), to try to find changes at different residues (peptides) that appeared to be correlated, even though the residues were not consecutive in the main chain. Such correlations suggest that the residues may be close to each other physically, even though not close in the sequence, allowing a contact map to be estimated. Building on recent work prior to 2018, AlphaFold 1 extended this by estimating a probability distribution for the distances between residues, effectively transforming the contact map into a distance map. It also used more advanced learning methods than previously to develop the inference. The code was not made publicly available, except to run on sequences of proteins in the 2018 CASP competition.
Laser microprobe mass spectrometer Particulate matter sampler Aerosol impaction Particle size analysis Hartonen, Kari; Laitinen, Totti; Riekkola, Marja-Liisa (2011). "Current instrumentation for aerosol mass spectrometry". TrAC Trends in Analytical Chemistry. 30 (9): 1486–1496. doi:10.1016/j.trac.2011.06.007. ISSN 0165-9936. Centre for Atmospheric Science TOF-AMS resources Q-AMS resources List of publications using all versions of the AMS Glossary of AMS terms
ADP + Pi + 2H+out ⇌ ATP + H2O + 2H+in ATP synthase lies across a cellular membrane and forms an aperture that protons can cross from areas of high concentration to areas of low concentration, imparting energy for the synthesis of ATP. This electrochemical gradient is generated by the electron transport chain and allows cells to store energy in ATP for later use. In prokaryotic cells ATP synthase lies across the plasma membrane, while in eukaryotic cells it lies across the inner mitochondrial membrane. Organisms capable of photosynthesis also have ATP synthase across the thylakoid membrane, which in plants is located in the chloroplast and in cyanobacteria is located in the cytoplasm. ATP synthase is present in all organisms studied. Eukaryotic ATP synthases are F-ATPases (which usually work as ATP synthases instead of ATPases in cellular environments) and running "in reverse" for an ATPase (ATPases catalyze the decomposition of ATP into ADP and a free phosphate ion). This article deals mainly with this type. An F-ATPase consists of two main subunits, FO and F1, which has a rotational motor mechanism allowing for ATP production.
2,5-Diketopiperazine is an organic compound with the formula (NHCH2C(O))2. The compound features a six-membered ring containing two amide groups at opposite positions in the ring. It was first compound containing a peptide bond to be characterized by X-ray crystallography in 1938. It is the parent of a large class of 2,5-Diketopiperazines (2,5-DKPs) with the formula (NHCH2(R)C(O))2 (R = H, CH3, etc.). They are ubiquitous peptides in nature. They are often found in fermentation broths and yeast cultures as well as embedded in larger more complex architectures in a variety of natural products as well as several drugs. In addition, they are often produced as degradation products of polypeptides, especially in foods and beverages. They have also been found in extraterrestrial objects such as comets and asteroids.
The enzyme 2-dehydro-3-deoxy-phosphogluconate aldolase (EC 4.1.2.14), commonly known as KDPG aldolase, catalyzes the chemical reaction 2-dehydro-3-deoxy-D-gluconate 6-phosphate ⇌ {\displaystyle \rightleftharpoons } pyruvate + D-glyceraldehyde 3-phosphate This enzyme belongs to the family of lyases, specifically the aldehyde-lyases, which cleave carbon-carbon bonds. It is used in the Entner–Doudoroff pathway in prokaryotes, feeding into glycolysis. 2-dehydro-3-deoxy-phosphogluconate aldolase is one of the two enzymes distinguishing this pathway from the more commonly known Embden–Meyerhof–Parnas pathway. This enzyme also participates in following 3 metabolic pathways: pentose phosphate pathway, pentose and glucuronate interconversions, and arginine and proline metabolism. In addition to the cleavage of 2-dehydro-3-deoxy-D-gluconate 6-phosphate, it is also found to naturally catalyze Schiff base formation between a lysine ε-amino acid group and carbonyl compounds, decarboxylation of oxaloacetate, and exchange of solvent protons with the methyl hydrogen atoms of pyruvate.
Sources: en.wikipedia.org
HPLC testing measures the presence and amount of one or more compounds in a liquid sample. It separates mixture components and records detector responses as peaks, which are compared with reference standards. Results are usually reported as concentrations or relative percentages.
Retention time is the interval between sample injection and the detector response for a given compound. It depends on the compound's interactions with the stationary and mobile phases under set conditions. Matching a retention time to a standard supports tentative identification but is not always unique.
HPLC alone can separate unknown compounds and provide retention times, but it often cannot identify them with certainty. Coupling HPLC to mass spectrometry gives mass information that improves identification. Confirmation usually requires comparison with reference standards or complementary techniques.
Validation establishes suitability for a new method, while verification confirms that a method works in a specific laboratory. Verification is often used when a validated method is adopted with existing equipment and staff. Both rely on documented acceptance criteria.