retention time comes up often in conversation and rarely with the context attached. Here we lay out the basics in order, then work through the practical considerations.
Last reviewed on 2026-02-17. Where a claim depends on a specific study, the study is described rather than over-claimed.
Reversed-phase chromatography dominates modern HPLC testing, using a nonpolar stationary phase such as chemically bonded octadecyl groups and a polar mobile phase of water mixed with organic solvent. Analytes partition between the mobile and stationary phases according to hydrophobicity. Gradient elution changes the mobile phase composition over time to separate compounds with a wide range of retention. Isocratic elution keeps the composition constant and is simpler for routine assays. Column temperature, pH, and flow rate influence selectivity, peak shape, and retention time, so these parameters are controlled during a validated method.
Detection in HPLC testing commonly relies on ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. A diode array detector records full spectra across a wavelength range, which helps identify co-eluting peaks. Mass spectrometry provides mass-to-charge ratios and can confirm molecular identity at low concentrations. The choice of detector depends on analyte structure, required sensitivity, and whether quantitation or identification is the goal. No single detector works for every compound, and method development often compares responses before selecting one.
Routine HPLC testing depends on controlled reagents, calibrated instruments, and documented procedures. Columns degrade over time, so retention times and peak shapes are monitored for drift. Mobile phases are filtered and degassed to prevent pump damage and detector noise. Reference standards must be traceable and stored under suitable conditions. Data handling systems record injections, calculations, and audit trails. Quality control samples interspersed with unknowns help detect errors during a run.
Developing an HPLC method begins with defining the purpose, such as quantifying a main component, measuring impurities, or confirming identity. Analysts select separation mode, column, mobile phase, detection, and sample preparation based on analyte properties and matrix. Experiments vary solvent strength, pH, buffer type, and temperature to achieve resolution between critical peaks. The goal is a robust method that produces reliable results across instruments and operators. Method development often involves trial runs and statistical optimization.
Validation demonstrates that a method is suitable for its intended use. Typical performance characteristics include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Regulators and standards organizations provide frameworks, but specific requirements depend on the application and jurisdiction. System suitability tests are run before sample analysis to confirm resolution, peak symmetry, retention time repeatability, and sensitivity. A validated method is not permanently fixed; changes may require partial or full revalidation.
| Property | Value | Notes |
|---|---|---|
| Separation mode | Reversed-phase | Most common for neutral and moderately polar analytes |
| Column particle size | 3–5 µm | Smaller particles improve resolution but raise backpressure |
| Mobile phase pH range | 2–8 | Silica-based columns may degrade outside this range |
| Typical flow rate | 1.0–2.0 mL/min | For analytical columns with 4.6 mm internal diameter |
| Common synonyms | HPLC, LC, high-pressure liquid chromatography | High-performance liquid chromatography is the standard expansion |
Several separation modes exist, including reversed-phase, normal-phase, ion-exchange, size-exclusion, and hydrophilic interaction liquid chromatography. Reversed-phase uses a nonpolar stationary phase with a polar mobile phase and is widely applied to small organic molecules. Gradient elution changes mobile phase composition during the run, while isocratic elution keeps it constant. Column chemistry, particle size, temperature, flow rate, and mobile phase pH all influence retention and resolution. Method development selects conditions that separate analytes from matrix components and from each other.
Detection commonly uses ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. Ultraviolet detection depends on molecular chromophores that absorb light at specific wavelengths. Mass spectrometry provides mass information and sensitive quantification, often after electrospray ionization. Before sample batches, performance checks examine resolution, elution time repeatability, peak symmetry, and plate count. Matrix effects and co-elution remain recognized uncertainties; formal validation studies and orthogonal detection help address them. Detector choice depends on analyte properties and required sensitivity.
Binding curves describe the binding behavior of ligand to a protein. Curves can be characterized by their shape, sigmoidal or hyperbolic, which reflect whether or not the protein exhibits cooperative or noncooperative binding behavior respectively. Typically, the x-axis describes the concentration of ligand and the y-axis describes the fractional saturation of ligands bound to all available binding sites. The Michaelis Menten equation is usually used when determining the shape of the curve. The Michaelis Menten equation is derived based on steady-state conditions and accounts for the enzyme reactions taking place in a solution. However, when the reaction takes place while the enzyme is bound to a substrate, the kinetics play out differently. Modeling with binding curves are useful when evaluating the binding affinities of oxygen to hemoglobin and myoglobin in the blood. Hemoglobin, which has four heme groups, exhibits cooperative binding. This means that the binding of oxygen to a heme group on hemoglobin induces a favorable conformation change that allows for increased binding favorability of oxygen for the next heme groups. In these circumstances, the binding curve of hemoglobin will be sigmoidal due to its increased binding favorability for oxygen. Since myoglobin has only one heme group, it exhibits noncooperative binding which is hyperbolic on a binding curve.
Cannabis Analytical Science Program (CASP) is a forum where the science of hemp and cannabis analysis can be discussed and cannabis standards and methods developed. Analytical Solutions Forum (ASF) brings global stakeholders together to identify emerging needs and technologies in scientific analysis of food and related products. === Botanical Ingredients and Dietary Supplement Integrity Program === AOAC’s Botanical Ingredient and Dietary Supplement Integrity (BIDSI) Program focuses on coordinating all future consensus-driven need for development, validation, and implementation of methods for the analysis of a wide range of botanical ingredients and dietary supplements. === Stakeholder Program on Infant Formula and Adult Nutritionals === Stakeholder Program on Infant Formula and Adult Nutritionals program (SPIFAN) develops consensus-based standards and methods to make infant formula and adult nutritionals safer for babies and adults to consume.
The positive transcription elongation factor, P-TEFb, is a multiprotein complex that plays an essential role in the regulation of transcription by RNA polymerase II (Pol II) in eukaryotes. Immediately following initiation Pol II becomes trapped in promoter proximal paused positions on the majority of human genes (Figure 1). P-TEFb is a cyclin dependent kinase that can phosphorylate the DRB sensitivity inducing factor (DSIF) and negative elongation factor (NELF), as well as the carboxyl terminal domain of the large subunit of Pol II and this causes the transition into productive elongation leading to the synthesis of mRNAs. P-TEFb is regulated in part by a reversible association with the 7SK snRNP. Treatment of cells with the P-TEFb inhibitors DRB or flavopidirol leads to loss of mRNA production and ultimately cell death. P-TEFb was identified and purified as a factor needed for the generation of long run-off transcripts using an in vitro transcription system derived from Drosophila cells.
After earning his doctorate in biochemistry, Lehninger held various faculty positions at the University of Wisconsin–Madison and the University of Chicago. In 1952, he went to the Johns Hopkins School of Medicine, assuming the title of DeLamar Professor of the Department of Biological Chemistry. He served in this position until 1978, when he was appointed to the role of University Professor of Medical Sciences. He held this title until his death in 1986. 1948 – Paul-Lewis Award in Enzyme Chemistry 1951 – Guggenheim Fellowship 1956 – Elected to the National Academy of Sciences 1959 – Elected to the American Academy of Arts and Sciences 1969 – Remsen Award of the American Chemical Society 1970 – American Philosophical Society 1986 – Passano Foundation Award Forthcoming in New Dictionary of Scientific Biography
In Taiwan, the Taiwan Transportation Safety Board (TTSB) is the independent government agency that is responsible for major transportation accident investigations. TTSB's predecessor was ASC, which was established in 1998. TTSB is under the administration of the Executive Yuan and independent from Civil Aviation Administration. The TTSB consisted of five to seven board members, including a chairman and a vice chairman, appointed by the Premier. The managing director of TTSB manages the day-to-day function of the organization, including accident investigations. In the United Kingdom, the agency responsible for investigation of civilian air crashes is the Air Accidents Investigation Branch (AAIB) of the Department for Transport. Its purpose is to establish the circumstances and causes of the accident and to make recommendations for their future avoidance.
Sources: en.wikipedia.org
Creatine is an organic acid naturally occurring in the body (and in red meats) that supplies energy to muscle cells for short bursts of energy (as required in lifting weights) via creatine phosphate replenishment of ATP. Scientific studies have shown that creatine supplementation can increase the consumer's strength, energy during performance, muscle mass, and recovery times after exercise. In addition, recent studies have also shown that creatine improves brain function and reduces mental fatigue. Some studies have suggested that consumption of creatine with protein and carbohydrates can have a greater effect than creatine combined with either protein or carbohydrates alone. While generally considered safe, long-term or excessive consumption of creatine may have an adverse effect on the kidneys, liver, or heart and should be avoided if any pre-existing conditions affecting these organs exist.
Plasma membranes also contain carbohydrates, predominantly glycoproteins, but with some glycolipids (cerebrosides and gangliosides). Carbohydrates are important in the role of cell-cell recognition in eukaryotes; they are located on the surface of the cell where they recognize host cells and share information. Viruses that bind to cells using these receptors cause an infection. For the most part, no glycosylation occurs on membranes within the cell; rather generally glycosylation occurs on the extracellular surface of the plasma membrane. The glycocalyx is an important feature in all cells, especially epithelia with microvilli. Recent data suggest the glycocalyx participates in cell adhesion, lymphocyte homing, and many others. The penultimate sugar is galactose and the terminal sugar is sialic acid, as the sugar backbone is modified in the Golgi apparatus. Sialic acid carries a negative charge, providing an external barrier to charged particles.
The Society holds an annual conference in late May or early June as well as topical conferences (at Asilomar State Beach in California and Sanibel Island, Florida) and a fall workshop, which is also focused on a single topic. Conferences on Mass Spectrometry and Allied Topics have been held yearly since 1953. International Mass Spectrometry Foundation List of female mass spectrometrists ASMS website
The pathway can be activated by a range of signals, including hormones, growth factors and components of the extracellular matrix (ECM). It is stimulated by binding of an extracellular ligand to a receptor tyrosine kinase (RTK) in the plasma membrane, causing receptor dimerization and cross-phosphorylation of tyrosine residues in the intracellular domains. The regulatory subunit p85 binds to phosphorylated tyrosine residues on the activated receptor via its Src homology 2 (SH2) domain. It then recruits the catalytic subunit p110 to form the fully active PI3K enzyme. Alternatively, adaptor molecule Grb2 binds to phospho-YXN motifs of the RTK and recruits p85 via Grb2-associated binding (GAB) scaffold protein. The p110 subunit can also be recruited independently of p85. For example, Grb2 can also bind the Ras-GEF Sos1, leading to activation of Ras. Ras-GTP then activates the p110 subunit of PI3K. Other adaptor molecules such as insulin receptor substrate (IRS) can also activate p110.
Sources: en.wikipedia.org
HPLC testing separates and quantifies components in a liquid sample. It is used to check identity, purity, concentration, or stability. The technique works best for compounds that dissolve and are not easily vaporized.
The pump maintains a steady flow rate and pressure, which keeps retention times reproducible. Pulsation or flow errors can shift peaks and distort quantitation. Modern pumps use feedback control to reduce these variations.
HPLC alone usually separates compounds but does not always identify them. Retention time matching with a known standard provides tentative identification. Coupling HPLC to mass spectrometry adds mass information that supports structural identification.
It is a set of checks performed before or during an HPLC run to confirm the system works as expected. Parameters may include resolution, tailing factor, theoretical plates, and retention time precision. Failure can trigger maintenance, method adjustment, or repeat analysis.